PATENTS PENDING
55
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
7. On the right side of the
platform, turn ground
switch adjustment screw
counter-clockwise to de-
activate the switch (FIG.
55-2). Next, turn adjust-
ment screw clockwise until
switch activates with an
audible “click” (FIG. 55-3).
Then, turn screw approxi-
mately 1/2-turn clockwise.
6. Repeat steps 4 and 5 to en-
sure adjustment is done cor-
rectly. Then turn screw clock-
wise 1 full turn and tighten
jam nut (FIG. 55-1).
ADJUSTMENT SCREW & JAM NUT, LH SIDE
FIG. 55-1
ADJUSTMENT
SCREW
JAM NUT
TURNING RH GROUND SWITCH
FIG. 55-3
ADJUSTMENT
SCREW
TURNING GROUND SWITCH CCW, RH SIDE
FIG. 55-2
ADJUSTMENT
SCREW
Komentáře k této Příručce