Maxon WL7-vers. C Návod k obsluze Strana 66

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 65
PATENTS PENDING
66
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
1. Position the platform at oor level
(FIG. 66-1).
2. Turn OFF power switch on pump
cover (FIG. 66-1).
PLATFORM AT FLOOR LEVEL
(LH SIDE SHOWN)
FIG. 66-1
POWER
SWITCH
INBOARD SWITCH ADJUSTMENT (IF REQUIRED)
NOTE: Do this procedure if the Controller reads “IBRS SW” when Inboard Rollstop is
locked in the up position.
The adjustment is done correctly if the Controller does not read “IBRS SW
when the Inboard Rollstop is locked in the up position.
3. Using the manual backup pump (FIG. 66-2),
lower the platform until inboard rollstop
(IBRS) is locked in the up position (FIG. 55-
1). Refer to Operation Manual for instruc-
tions to operate the manual pump.
USING BACKUP PUMP TO UNFOLD
(LIFT WITH LH PUMP)
FIG. 66-2
RELEASE
VALVE
BACKUP PUMP
HANDLE
Zobrazit stránku 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 72 73 74

Komentáře k této Příručce

Žádné komentáře