Maxon WL7-vers. C Návod k obsluze Strana 67

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 66
PATENTS PENDING
67
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
PUSH IBRS
AGAINST LOCK
4. Push the inboard rollstop back
against the lock as if a wheel-
chair is pushing on the rollstop
(FIG. 67-1).
5. On the inboard rollstop switch,
loosen screws (1) and (2) one-half
turn (FIG. 67-2A). Next, rotate
switch bracket clockwise until the
switch activates with an audible
“click”. Then tighten screws (1)
and (2) securely.
6. Turn ON power switch on pump
cover (FIG. 67-2A). Then raise
(UP) the platform to oor level
(FIG. 54-1). Verify that “INBD
SW” is not displayed on the lift
controller. If necessary repeat
this procedure.
PLATFORM BELOW FLOOR LEVEL,
WITH IBRS UP (LH SIDE SHOWN)
FIG. 67-1
PLATFORM BELOW FLOOR LEVEL,
WITH IBRS UP (LH SIDE SHOWN)
FIG. 67-2A
CUT-AWAY VIEW OF
LH VERTICAL ARM
& IBRS SWITCH
FIG. 67-2B
SCREW (2)
SWITCH
(REF)
SCREW (1)
SWITCH
BRACKET
IBRS
POWER SWITCH
Zobrazit stránku 66